{"product_id":"nasan-medical-sanjeevani-1006-defibrillator","title":"Nasan Medical Sanjeevani 1006 Defibrillator","description":"\u003ch3 data-path-to-node=\"1\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\" id=\"p-rc_1b1ebf3fa4c7c3b6-695\"\u003e\u003cspan class=\"citation-2057 citation-end-2057\"\u003eThe Nasan Medical Sanjeevani 1006 is an advanced, life-saving biphasic defibrillator engineered for rapid medical response and multi-parameter monitoring.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-2056 citation-end-2056\"\u003eFeaturing a bright 7-inch color TFT display and an integrated 2-inch thermal printer, the unit supports quick 1-2-3 step manual defibrillation alongside optional diagnostic features like AED, SpO2, NIBP, EtCO2, and Pacing.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e It uses a Biphasic Truncated Exponential (BTE) waveform to ensure maximum efficacy in restoring normal cardiac rhythms while delivering critical patient data tracking for medical teams. \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003e7-inch Color TFT Screen (150 mm \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"32\"\u003e$\\times$\u003c\/span\u003e 90 mm display area)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eDefibrillator Waveform\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003eBiphasic Truncated Exponential (BTE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eEnergy Selection (Manual)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003e2 to 200 Joules across 12 steps \u003ci data-path-to-node=\"5,3,1,0\" data-index-in-node=\"32\"\u003e(Optional up to 360J)\u003c\/i\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003eCharging Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003e6 to 8 seconds on Mains power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eSynchronous Cardioversion\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003eEnergy delivery starts within 60 ms of the QRS Peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003ePatient Impedance Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003e25 \u003cspan class=\"math-inline\" data-math=\"\\Omega\" data-index-in-node=\"3\"\u003e$\\Omega$\u003c\/span\u003e to 150 \u003cspan class=\"math-inline\" data-math=\"\\Omega\" data-index-in-node=\"17\"\u003e$\\Omega$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003e\u003cb data-path-to-node=\"5,7,0,0\" data-index-in-node=\"0\"\u003eECG Frequency Response\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003e0.5 Hz to 35 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003e\u003cb data-path-to-node=\"5,8,0,0\" data-index-in-node=\"0\"\u003eECG Lead Selection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003eLead I, II, and III (via paddles\/pads or 5-lead cable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,0,0\"\u003e\u003cb data-path-to-node=\"5,9,0,0\" data-index-in-node=\"0\"\u003eCMRR\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026gt;\" data-index-in-node=\"0\"\u003e$\u0026gt;$\u003c\/span\u003e 90 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,0,0\"\u003e\u003cb data-path-to-node=\"5,10,0,0\" data-index-in-node=\"0\"\u003eMemory Storage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,1,0\"\u003e250 shock events with 10 seconds of recorded ECG data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,0,0\"\u003e\u003cb data-path-to-node=\"5,11,0,0\" data-index-in-node=\"0\"\u003eIntegrated Recorder \/ Printer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,1,0\"\u003e2-inch (58mm) built-in thermal printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,0,0\"\u003e\u003cb data-path-to-node=\"5,12,0,0\" data-index-in-node=\"0\"\u003ePower Input\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,1,0\"\u003e90 - 260 VAC, 50 Hz, Single Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,0,0\"\u003e\u003cb data-path-to-node=\"5,13,0,0\" data-index-in-node=\"0\"\u003eInternal Battery\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,1,0\"\u003e12V \/ 4.5Ah Rechargeable Sealed Lead Acid (SLA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,14,0,0\"\u003e\u003cb data-path-to-node=\"5,14,0,0\" data-index-in-node=\"0\"\u003eBattery Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,14,1,0\"\u003e3 to 4 hours backup time or 70 - 100 shocks at max energy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,15,0,0\"\u003e\u003cb data-path-to-node=\"5,15,0,0\" data-index-in-node=\"0\"\u003eDimensions \u0026amp; Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,15,1,0\"\u003e~ 275 \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"6\"\u003e$\\times$\u003c\/span\u003e 323 \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"17\"\u003e$\\times$\u003c\/span\u003e 200 mm (without paddles) | Weight: ~ 8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eIntuitive 1-2-3 Operation:\u003c\/b\u003e Simple interface layout that ensures clear, step-by-step guidance under high-pressure cardiac emergencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_1b1ebf3fa4c7c3b6-696\"\u003e\u003cspan class=\"citation-2055\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2055\"\u003eVariable Energy Selection:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2055 citation-end-2055\"\u003e Comprehensive manual adjustments ranging from low-energy settings (2J) up to standard therapeutic shocks.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_1b1ebf3fa4c7c3b6-697\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDual Patient Paddle Assembly:\u003c\/b\u003e\u003cspan class=\"citation-2054 citation-end-2054\"\u003e Integrated adult and pediatric paddles built into a single, cohesive handle to minimize switching time.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eSynchronous Cardioversion:\u003c\/b\u003e Detects QRS peaks precisely to deliver synchronized therapy for unstable atrial or ventricular arrhythmias.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\" id=\"p-rc_1b1ebf3fa4c7c3b6-698\"\u003e\u003cspan class=\"citation-2053\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2053\"\u003eVoice Prompt Facility:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2053 citation-end-2053\"\u003e Clear voice alerts and text readouts assist operators dynamically through the rescue process.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eIntegrated 2-Inch Thermal Printer:\u003c\/b\u003e Automatically documents the event status, printing 5 seconds of pre- and post-shock ECG data along with date, time, and energy parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\" id=\"p-rc_1b1ebf3fa4c7c3b6-699\"\u003e\u003cspan class=\"citation-2052\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2052\"\u003eModular Multi-Parameter Flexibility:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2052 citation-end-2052\"\u003e Fully upgradeable from a standard manual defibrillator into a comprehensive multi-para monitor (adding AED mode, Non-Invasive Blood Pressure, SpO2, and End-Tidal CO2 monitoring).\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\" id=\"p-rc_1b1ebf3fa4c7c3b6-700\"\u003e\u003cspan class=\"citation-2051\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2051\"\u003eComprehensive Data Retention:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2051 citation-end-2051\"\u003e Features an internal summary log that stores up to 250 distinct shock events alongside historical ECG tracking for seamless clinical review.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eIntensive Care Units (ICU) \u0026amp; Operating Rooms:\u003c\/b\u003e Continuous monitoring of unstable cardiac patients with quick manual override capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eEmergency Rooms (ER) \u0026amp; Trauma Centers:\u003c\/b\u003e High-speed charging options for immediate code-blue responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eAmbulatory \u0026amp; In-Hospital Transport:\u003c\/b\u003e Built-in handle and deep battery backup allow it to operate safely on crash carts while moving patients between wards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eNasan Medical Sanjeevani 1006 Defibrillator Main Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\" id=\"p-rc_1b1ebf3fa4c7c3b6-701\"\u003e\u003cspan class=\"citation-2050 citation-end-2050\"\u003eIntegrated External Adult \u0026amp; Pediatric Combination Paddles\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003e5-Lead ECG Patient Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eThermal Printing Paper Roll (58mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eAC Power Input Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\" id=\"p-rc_1b1ebf3fa4c7c3b6-702\"\u003e\u003cspan class=\"citation-2049 citation-end-2049\"\u003eRechargeable 12V Internal Battery (Pre-installed)\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eUser Operation Manual \u0026amp; Certificate of Calibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974114525402,"sku":"7723","price":131300.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/9527017.webp?v=1781178713","url":"https:\/\/www.kaaryamedical.com\/products\/nasan-medical-sanjeevani-1006-defibrillator","provider":"KDS Enterprise","version":"1.0","type":"link"}