{"product_id":"medevo-spa112-syringe-infusion-pump","title":"Medevo SPA112 Syringe infusion Pump","description":"\u003ch3 data-path-to-node=\"2\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eMedevo SPA112\u003c\/b\u003e is a compact, stackable single-channel syringe pump designed for precise and safe intravenous administration of critical drugs and fluids. It features a dual-CPU safety architecture to ensure reliable performance during continuous medical therapies and is designed with an emphasis on clinical workflow efficiency, featuring intuitive digital controls and long-range visibility.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"6\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,0,0\"\u003e\u003cb data-path-to-node=\"6,1,0,0\" data-index-in-node=\"0\"\u003eChannel Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,1,0\"\u003eSingle-channel, horizontally stackable design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,0,0\"\u003e\u003cb data-path-to-node=\"6,2,0,0\" data-index-in-node=\"0\"\u003eCompatible Syringe Sizes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,1,0\"\u003e5 ml, 10 ml, 20 ml (or 30 ml), and 50 ml (or 60 ml)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,3,0,0\"\u003e\u003cb data-path-to-node=\"6,3,0,0\" data-index-in-node=\"0\"\u003eInfusion Modes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,3,1,0\"\u003eRate Mode, Rate-Time, Rate-VTBI, Time-VTBI, Body Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,0,0\"\u003e\u003cb data-path-to-node=\"6,4,0,0\" data-index-in-node=\"0\"\u003eInfusion Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,1,0\"\u003e±2% (highly precise flow control)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,5,0,0\"\u003e\u003cb data-path-to-node=\"6,5,0,0\" data-index-in-node=\"0\"\u003eVolume to be Infused (VTBI)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,5,1,0\"\u003e0 to 9999.9 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,6,0,0\"\u003e\u003cb data-path-to-node=\"6,6,0,0\" data-index-in-node=\"0\"\u003eFlow Rate Steps\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,6,1,0\"\u003e0.1 ml\/h (for rates less than 100 ml\/h); 1 ml\/h (for rates greater than or equal to 100 ml\/h)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,7,0,0\"\u003e\u003cb data-path-to-node=\"6,7,0,0\" data-index-in-node=\"0\"\u003eFlow Rate Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"6,7,1,0\"\u003e• \u003cb data-path-to-node=\"6,7,1,0\" data-index-in-node=\"2\"\u003e5ml syringe:\u003c\/b\u003e 0.1 to 150 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,7,1,1\"\u003e\n\u003cp data-path-to-node=\"6,7,1,2\"\u003e• \u003cb data-path-to-node=\"6,7,1,2\" data-index-in-node=\"2\"\u003e10ml syringe:\u003c\/b\u003e 0.1 to 300 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,7,1,3\"\u003e\n\u003cp data-path-to-node=\"6,7,1,4\"\u003e• \u003cb data-path-to-node=\"6,7,1,4\" data-index-in-node=\"2\"\u003e20ml syringe:\u003c\/b\u003e 0.1 to 600 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,7,1,5\"\u003e\n\u003cp data-path-to-node=\"6,7,1,6\"\u003e• \u003cb data-path-to-node=\"6,7,1,6\" data-index-in-node=\"2\"\u003e30ml syringe:\u003c\/b\u003e 0.1 to 900 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,7,1,7\"\u003e\n\u003cp data-path-to-node=\"6,7,1,8\"\u003e• \u003cb data-path-to-node=\"6,7,1,8\" data-index-in-node=\"2\"\u003e50\/60ml syringe:\u003c\/b\u003e 0.1 to 1200 ml\/h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,8,0,0\"\u003e\u003cb data-path-to-node=\"6,8,0,0\" data-index-in-node=\"0\"\u003eBolus \/ Purge Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"6,8,1,0\"\u003e• \u003cb data-path-to-node=\"6,8,1,0\" data-index-in-node=\"2\"\u003e5ml:\u003c\/b\u003e 0.1 to 200 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,8,1,1\"\u003e\n\u003cp data-path-to-node=\"6,8,1,2\"\u003e• \u003cb data-path-to-node=\"6,8,1,2\" data-index-in-node=\"2\"\u003e10ml:\u003c\/b\u003e 0.1 to 400 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,8,1,3\"\u003e\n\u003cp data-path-to-node=\"6,8,1,4\"\u003e• \u003cb data-path-to-node=\"6,8,1,4\" data-index-in-node=\"2\"\u003e20ml:\u003c\/b\u003e 0.1 to 800 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,8,1,5\"\u003e\n\u003cp data-path-to-node=\"6,8,1,6\"\u003e• \u003cb data-path-to-node=\"6,8,1,6\" data-index-in-node=\"2\"\u003e30ml:\u003c\/b\u003e 0.1 to 1200 ml\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,8,1,7\"\u003e\n\u003cp data-path-to-node=\"6,8,1,8\"\u003e• \u003cb data-path-to-node=\"6,8,1,8\" data-index-in-node=\"2\"\u003e50\/60ml:\u003c\/b\u003e 0.1 to 1800 ml\/h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,0,0\"\u003e\u003cb data-path-to-node=\"6,9,0,0\" data-index-in-node=\"0\"\u003eKVO (Keep Vein Open) Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,1,0\"\u003eAdjustable from 0.1 to 5.0 ml\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,10,0,0\"\u003e\u003cb data-path-to-node=\"6,10,0,0\" data-index-in-node=\"0\"\u003eOcclusion Pressure Levels\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,10,1,0\"\u003e3 levels adjustable (Low, Medium, High)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,11,0,0\"\u003e\u003cb data-path-to-node=\"6,11,0,0\" data-index-in-node=\"0\"\u003eMax Infusion Pressure\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,11,1,0\"\u003e120 KPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,12,0,0\"\u003e\u003cb data-path-to-node=\"6,12,0,0\" data-index-in-node=\"0\"\u003eDrug Library\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,12,1,0\"\u003eBuilt-in list supporting up to 20 drugs with drug code display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,13,0,0\"\u003e\u003cb data-path-to-node=\"6,13,0,0\" data-index-in-node=\"0\"\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,13,1,0\"\u003e3.5-inch color LCD Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,14,0,0\"\u003e\u003cb data-path-to-node=\"6,14,0,0\" data-index-in-node=\"0\"\u003eBattery Type \u0026amp; Runtime\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,14,1,0\"\u003eLithium Battery (11.1V \/ 2000mAh); provides greater than 8 hours of backup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,15,0,0\"\u003e\u003cb data-path-to-node=\"6,15,0,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,15,1,0\"\u003eAC: 100–240V, 50Hz\/60Hz (Optional Ambulance DC: 12V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,16,0,0\"\u003e\u003cb data-path-to-node=\"6,16,0,0\" data-index-in-node=\"0\"\u003eDimensions \u0026amp; Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,16,1,0\"\u003e26 x 21.5 x 11 cm; approximately 2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,17,0,0\"\u003e\u003cb data-path-to-node=\"6,17,0,0\" data-index-in-node=\"0\"\u003eSafety Classification\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,17,1,0\"\u003eClass I, Type CF, IPX4 splash-proof rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eDual-CPU Monitoring Architecture:\u003c\/b\u003e Utilizes a master CPU and a monitoring CPU simultaneously to prevent hardware failures and ensure consistent infusion standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eAutomatic Syringe Recognition:\u003c\/b\u003e Automatically detects the brand and physical size of the syringe loaded into the clamp.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eComprehensive Alarm Systems:\u003c\/b\u003e Features audible and visible alerts for critical safety parameters: Auto Self-Test failure, Syringe Dislocation, Occlusion, Near End, Syringe Empty, VTBI Completion, Low Battery \/ Battery Exhausted, Motor Malfunction, Circuit Error, and AC Power Disconnection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\" id=\"p-rc_10f1c9c2f8311390-233\"\u003e\u003cspan class=\"citation-620\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-620\"\u003eUser-Friendly Numeric Input:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-620 citation-end-620\"\u003e Built-in numeric keypad allows for immediate, precise parameter configuration rather than scrolling through endless menus.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\" id=\"p-rc_10f1c9c2f8311390-234\"\u003e\u003cspan class=\"citation-619\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-619\"\u003eHigh-Visibility Display:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-619 citation-end-619\"\u003e Features a crisp 3.5-inch color LCD screen designed to remain legible up to a distance of 5 meters.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\" id=\"p-rc_10f1c9c2f8311390-235\"\u003e\u003cspan class=\"citation-618\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-618\"\u003eSpace-Saving Space Stations:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-618 citation-end-618\"\u003e Free stacking functionality allows multiple single pumps to slot together cleanly on a single IV pole without specialized hardware.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\" id=\"p-rc_10f1c9c2f8311390-236\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eOne-Button Night Mode:\u003c\/b\u003e\u003cspan class=\"citation-617 citation-end-617\"\u003e One-click adjustment dims the screen backlight and indicators to minimize visual disturbance for the patient during resting hours.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\" id=\"p-rc_10f1c9c2f8311390-237\"\u003e\u003cspan class=\"citation-616\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-616\"\u003eExtension Line Grip:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-616 citation-end-616\"\u003e Includes a purpose-designed secure routing grip to manage lines cleanly and reduce pulling tension on the syringe.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\" id=\"p-rc_10f1c9c2f8311390-238\"\u003e\u003cspan class=\"citation-615\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-615\"\u003eIntensive Care Units (ICU \u0026amp; NICU):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-615 citation-end-615\"\u003e Perfect for managing precise micro-dosages of vasoactive or neonatal medications where multi-pump space allocation is highly limited.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eOperating Theatres (OT) \u0026amp; Anesthesia:\u003c\/b\u003e Allows continuous, metered delivery of intravenous anesthetics and muscle relaxants during surgical operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003ePatient Transfers \/ Ambulance Transport:\u003c\/b\u003e Due to its light 2 kg frame, robust 8-hour lithium battery, and optional 12V DC input compatibility, it handles mobile emergency transport seamlessly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\" id=\"p-rc_10f1c9c2f8311390-239\"\u003e\u003cspan class=\"citation-614 citation-end-614\"\u003e1x Medevo SPA112 Syringe Pump Unit\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\" id=\"p-rc_10f1c9c2f8311390-240\"\u003e\u003cspan class=\"citation-613 citation-end-613\"\u003e1x AC Power Cable\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e1x IV Pole Mounting Clamp Attachment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\" id=\"p-rc_10f1c9c2f8311390-241\"\u003e\u003cspan class=\"citation-612 citation-end-612\"\u003e1x User Manual \u0026amp; Documentation Guide\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974106071258,"sku":"7618","price":21000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/medevo-spa112-syringe-infusion-pump-1000x1000.jpg?v=1782656889","url":"https:\/\/www.kaaryamedical.com\/products\/medevo-spa112-syringe-infusion-pump","provider":"KDS Enterprise","version":"1.0","type":"link"}