{"product_id":"mdk-syringe-pump-06-non-touch","title":"MDK SYRINGE PUMP -06 Non Touch","description":"\u003cp\u003e\u003cstrong\u003eMachine Specificatipons\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum infusion pressure-\u0026gt;150kPa\u003c\/li\u003e\n\u003cli\u003eOcclusion Alarm: Detects occlusions in the infusion line and alerts the user\u003c\/li\u003e\n\u003cli\u003eAir-in-Line Alarm: Detects air in the infusion line and alerts the user\u003c\/li\u003e\n\u003cli\u003eLow Battery Alarm: Alerts the user when the battery level is low\u003c\/li\u003e\n\u003cli\u003eDisplay: Backlit LCD display showing infusion parameters, alarms, and battery status. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Feature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel: MDK -06 \u003c\/li\u003e\n\u003cli\u003eManufacturer: Medecin (a brand of Fresenius Kabi)\u003c\/li\u003e\n\u003cli\u003eType: Syringe Pump\u003c\/li\u003e\n\u003cli\u003eDimensions: 140 mm (W) x 220 mm (H) x 320 mm (D)\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 2.5 kg (5.5 lbs)\u003c\/li\u003e\n\u003cli\u003ePower Supply: 100-240 VAC, 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eBattery Life: Up to 8 hours (rechargeable battery)\u003c\/li\u003e\n\u003cli\u003eFlow Rate: 0.1-120 mL\/h (in 0.1 mL\/h increments)\u003c\/li\u003e\n\u003cli\u003eSyringe Size: 10mL, 20mL, 30mL, and 60mL\u003c\/li\u003e\n\u003cli\u003ePumping Mode: Continuous, Intermittent, and Bolus\u003c\/li\u003e\n\u003cli\u003eInfusion Volume: 0.1-9999 mL (in 0.1 mL increments)\u003c\/li\u003e\n\u003cli\u003eInfusion Time: 0-999 minutes (in 1minute increments)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark: Conforms to EU Medical Device Directive 93\/42\/EEC. \u003c\/li\u003e\n\u003cli\u003eFDA Clearance: 510(k) cleared by the US FDA.\u003c\/li\u003e\n\u003cli\u003eISO Certification: Meets ISO 13485:2016 standards for medical device quality management systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100.059%; height: 302.719px;\" data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0,0\"\u003eModel Name\/Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003eMDK -06 (Non-Touch variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0,0\"\u003eInfusion Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003e\u003cspan data-index-in-node=\"0\" data-math=\"\\pm 2\\%\" class=\"math-inline\"\u003e$\\pm 2\\%$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0,0\"\u003eSyringe Size Compatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003e2 ml, 5 ml, 10 ml, 20 ml, 30 ml, and 50\/60 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,4,0,0\"\u003eVolume Infused (VTBI)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003e0.1 to 9999.9 ml (adjustable in steps of 0.1 ml)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,5,0,0\"\u003eOcclusion Pressure Levels\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003eHigh (\u003cspan data-index-in-node=\"6\" data-math=\"100 \\text{ kPa}\" class=\"math-inline\"\u003e$100 \\text{ kPa}$\u003c\/span\u003e), Low (\u003cspan data-index-in-node=\"29\" data-math=\"50 \\text{ kPa}\" class=\"math-inline\"\u003e$50 \\text{ kPa}$\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 165.562px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 165.562px;\"\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,6,0,0\"\u003eKVO (Keep Vein Open) Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 165.562px;\"\u003e\n\u003cp data-path-to-node=\"3,6,1,0\"\u003e• Flow Rate \u003cspan data-index-in-node=\"12\" data-math=\"\\ge 10\\text{ ml\/h}\" class=\"math-inline\"\u003e$\\ge 10\\text{ ml\/h}$\u003c\/span\u003e: KVO is \u003cspan data-index-in-node=\"39\" data-math=\"3\\text{ ml\/h}\" class=\"math-inline\"\u003e$3\\text{ ml\/h}$\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-path-to-node=\"3,6,1,1\"\u003e\n\u003cp data-path-to-node=\"3,6,1,2\"\u003e• Flow Rate \u003cspan data-index-in-node=\"12\" data-math=\"1 \\text{ to } 10\\text{ ml\/h}\" class=\"math-inline\"\u003e$1 \\text{ to } 10\\text{ ml\/h}$\u003c\/span\u003e: KVO is \u003cspan data-index-in-node=\"49\" data-math=\"1\\text{ ml\/h}\" class=\"math-inline\"\u003e$1\\text{ ml\/h}$\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr data-path-to-node=\"3,6,1,3\"\u003e\n\u003cp data-path-to-node=\"3,6,1,4\"\u003e• Flow Rate \u003cspan data-index-in-node=\"12\" data-math=\"\u0026lt; 1\\text{ ml\/h}\" class=\"math-inline\"\u003e$\u0026lt; 1\\text{ ml\/h}$\u003c\/span\u003e: KVO = Current Flow Rate\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.3688%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,7,0,0\"\u003eSafety Classification\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.0763%; height: 19.5938px;\"\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003eClass II, Type CF, IPX2 waterpro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e \u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e \u003c\/p\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":48237626884314,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/www.kaaryamedical.com\/products\/mdk-syringe-pump-06-non-touch","provider":"KDS Enterprise","version":"1.0","type":"link"}