{"product_id":"maestros-vital-wave-biphasic-defibrillator","title":"Maestros Vital Wave Biphasic Defibrillator","description":"\u003ch3 data-path-to-node=\"1\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\" id=\"p-rc_e93f6dbafdf76336-723\"\u003e\u003cspan class=\"citation-2130 citation-end-2130\"\u003eThe Maestros Vital Wave is an advanced, highly portable biphasic defibrillator monitor designed to provide immediate cardiac resuscitation and real-time monitoring in critical care environments.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e Utilizing low-energy biphasic waveform technology, it reduces myocardial trauma while optimizing defibrillation efficacy. \u003cspan class=\"citation-2129 citation-end-2129\"\u003eEquipped with a bright, high-resolution 7-inch color display and multi-mode clinical operational capabilities, it allows healthcare professionals to handle sudden cardiac arrest and manage underlying arrhythmias confidently.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003eOperating Modes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003eManual Defibrillation, Synchronized Cardioversion, AED mode \u003ci data-path-to-node=\"5,1,1,0\" data-index-in-node=\"60\"\u003e(Pacer available on Pro version)\u003c\/i\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eWaveform Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003eBiphasic truncated exponential\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eEnergy Selection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003eVariable settings up to 270 Joules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003eCharging Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003eLess than 8 seconds to maximum 270 Joules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eDisplay Screen\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003e7-inch Diagonal Color TFT Display (800 x 480 pixels, dual-waveform display)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003eECG Acquisition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003e3 \/ 5 Lead patient cable or direct external paddles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003e\u003cb data-path-to-node=\"5,7,0,0\" data-index-in-node=\"0\"\u003eECG Frequency Response\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003e0.05 Hz to 40 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003e\u003cb data-path-to-node=\"5,8,0,0\" data-index-in-node=\"0\"\u003eCMRR \/ Input Impedance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026gt;\" data-index-in-node=\"0\"\u003e$\u0026gt;$\u003c\/span\u003e 100 dB \/ \u003cspan class=\"math-inline\" data-math=\"\u0026gt;\" data-index-in-node=\"13\"\u003e$\u0026gt;$\u003c\/span\u003e 100 M$\\Omega$\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,9,0,0\"\u003e\u003cb data-path-to-node=\"5,9,0,0\" data-index-in-node=\"0\"\u003eHeart Rate Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,9,1,0\"\u003e30 to 240 bpm (\u003cspan class=\"math-inline\" data-math=\"\\pm\" data-index-in-node=\"15\"\u003e$\\pm$\u003c\/span\u003e 2 bpm accuracy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,10,0,0\"\u003e\u003cb data-path-to-node=\"5,10,0,0\" data-index-in-node=\"0\"\u003eEvent Storage \u0026amp; Trend\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,10,1,0\"\u003eUp to 24 hours of event trends and system data logging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,11,0,0\"\u003e\u003cb data-path-to-node=\"5,11,0,0\" data-index-in-node=\"0\"\u003eRecorder\/Printer Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,11,1,0\"\u003eBuilt-in High-Resolution Thermal Array Recorder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,12,0,0\"\u003e\u003cb data-path-to-node=\"5,12,0,0\" data-index-in-node=\"0\"\u003ePrinter Paper Size\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,12,1,0\"\u003e57 mm \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"6\"\u003e$\\times$\u003c\/span\u003e 20 Meters roll (25 mm\/sec printing speed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,13,0,0\"\u003e\u003cb data-path-to-node=\"5,13,0,0\" data-index-in-node=\"0\"\u003ePower Input\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,13,1,0\"\u003eAC 230 V, 50 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,14,0,0\"\u003e\u003cb data-path-to-node=\"5,14,0,0\" data-index-in-node=\"0\"\u003eBattery Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,14,1,0\"\u003e14.8 V \/ 4400 mAh Rechargeable Lithium-Polymer (or Li-ion variants)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,15,0,0\"\u003e\u003cb data-path-to-node=\"5,15,0,0\" data-index-in-node=\"0\"\u003eBattery Backup Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,15,1,0\"\u003e40 to 50 max-energy shocks, or over 3 hours of continuous ECG monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,16,0,0\"\u003e\u003cb data-path-to-node=\"5,16,0,0\" data-index-in-node=\"0\"\u003eBattery Charge Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,16,1,0\"\u003eApprox. 8 hours for complete recharge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,17,0,0\"\u003e\u003cb data-path-to-node=\"5,17,0,0\" data-index-in-node=\"0\"\u003eEnclosure Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,17,1,0\"\u003eDust \u0026amp; Water Resistant (IP44 Rated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6091%;\"\u003e\u003cspan data-path-to-node=\"5,18,0,0\"\u003e\u003cb data-path-to-node=\"5,18,0,0\" data-index-in-node=\"0\"\u003eDimensions \u0026amp; Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.9953%;\"\u003e\u003cspan data-path-to-node=\"5,18,1,0\"\u003e403 (L) \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"8\"\u003e$\\times$\u003c\/span\u003e 324 (W) \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"23\"\u003e$\\times$\u003c\/span\u003e 152 (H) mm \/ Net Weight: 5.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\" id=\"p-rc_e93f6dbafdf76336-724\"\u003e\u003cspan class=\"citation-2128\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2128\"\u003eBiphasic Technology:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2128 citation-end-2128\"\u003e Delivers rapid therapeutic shocks utilizing low energy curves that minimize post-shock complications compared to traditional monophasic units.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_e93f6dbafdf76336-725\"\u003e\u003cspan class=\"citation-2127\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2127\"\u003eSmart Voice \u0026amp; Visual Prompts:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2127 citation-end-2127\"\u003e Built-in guidance protocols that comply with AHA (American Heart Association) and ERC guidelines to step the operator through emergency actions safely.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_e93f6dbafdf76336-726\"\u003e\u003cspan class=\"citation-2126\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2126\"\u003ePaddle Contact Indication:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2126 citation-end-2126\"\u003e Features color-coded contact status feedback on the screen to ensure adequate skin impedance before delivering a shock.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\" id=\"p-rc_e93f6dbafdf76336-727\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eComprehensive ECG Diagnostics:\u003c\/b\u003e\u003cspan class=\"citation-2125 citation-end-2125\"\u003e Supports visual monitoring of 2 simultaneous waveforms alongside heart rate (HR) and selected energy readouts.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\" id=\"p-rc_e93f6dbafdf76336-728\"\u003e\u003cspan class=\"citation-2124\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2124\"\u003eUpgradeability Paths:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2124 citation-end-2124\"\u003e The base monitoring architecture is physically engineered to accept future add-on upgrades for \u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"SpO_2\" data-index-in-node=\"117\"\u003e$SpO_2$\u003c\/span\u003e\u003cspan class=\"citation-2123 citation-end-2123\"\u003e (pulse oximetry) and NIBP (non-invasive blood pressure) tracking.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eAdult \u0026amp; Pediatric Cross-Compatibility:\u003c\/b\u003e Incorporates a dual-paddles system where outer adult plates slide off easily to reveal integrated infant\/pediatric paddles beneath.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\" id=\"p-rc_e93f6dbafdf76336-729\"\u003e\u003cspan class=\"citation-2122\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2122\"\u003eAutomated Self-Testing:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2122 citation-end-2122\"\u003e Performs automated internal self-checks on startup, displaying a \"Ready\" indicator directly on-screen to guarantee clinical availability.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eIntegrated Printing Records:\u003c\/b\u003e Detailed documentation prints instantly upon discharge, detailing the timestamp, patient parameters, pre-shock ECG waveform, selected Joules, and exact energy delivered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\" id=\"p-rc_e93f6dbafdf76336-730\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eHospital Crash Carts:\u003c\/b\u003e\u003cspan class=\"citation-2121 citation-end-2121\"\u003e Serves as the primary line of emergency defense inside ICUs, Operation Theaters (OT), and Emergency Rooms (ER).\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eAmbulance \u0026amp; Mobile Medical Units:\u003c\/b\u003e Compact layout, rugged IP44 footprint, and independent 3-hour battery capacity make it ideal for pre-hospital transit vehicles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eCardiac Care Units (CCU):\u003c\/b\u003e Utilized for controlled elective synchronized cardioversion procedures to treat atrial fibrillation or flutter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\" id=\"p-rc_e93f6dbafdf76336-731\"\u003e\u003cspan class=\"citation-2120 citation-end-2120\"\u003eMaestros Vital Wave Biphasic Defibrillator Main Unit\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003ePair of External Defibrillation Paddles (Adult with hidden slide-out Pediatric plates)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\" id=\"p-rc_e93f6dbafdf76336-732\"\u003e\u003cspan class=\"citation-2119 citation-end-2119\"\u003e3-Lead \/ 5-Lead Patient ECG Cable Assembly\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\" id=\"p-rc_e93f6dbafdf76336-733\"\u003e\u003cspan class=\"citation-2118 citation-end-2118\"\u003eDisposable ECG Electrodes (Starter Pack)\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eMultifunction Therapy\/AED Pads (if ordered with AED-specific configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\" id=\"p-rc_e93f6dbafdf76336-734\"\u003e\u003cspan class=\"citation-2117 citation-end-2117\"\u003eHigh-Capacity Rechargeable Battery Pack (Pre-installed)\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\" id=\"p-rc_e93f6dbafdf76336-735\"\u003e\u003cspan class=\"citation-2116 citation-end-2116\"\u003eThermal Array Recording Paper Roll\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eMedical Grade Conductive Gel Bottle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,8,0\" id=\"p-rc_e93f6dbafdf76336-736\"\u003e\u003cspan class=\"citation-2115 citation-end-2115\"\u003eAC Power Cord\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,9,0\"\u003eUser Operation Manual \u0026amp; Quick Reference Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974114492634,"sku":"7720","price":95167.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/677612208.webp?v=1781179256","url":"https:\/\/www.kaaryamedical.com\/products\/maestros-vital-wave-biphasic-defibrillator","provider":"KDS Enterprise","version":"1.0","type":"link"}