{"product_id":"kaarya-sp08-portable-syring-pump","title":"Kaarya SP08 Portable Syringe Pump","description":"\u003ch3 data-path-to-node=\"1\" class=\"\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"4\" class=\"\"\u003eSP08 Portable Syringe Pump\u003c\/b\u003e\u003cspan class=\"\"\u003e is an advanced,\u003c\/span\u003e\u003cspan class=\"\"\u003e highly reliable,\u003c\/span\u003e\u003cspan class=\"\"\u003e and compact medical device designed to deliver fluids,\u003c\/span\u003e\u003cspan class=\"\"\u003e critical medications,\u003c\/span\u003e\u003cspan class=\"\"\u003e and blood products in measured,\u003c\/span\u003e\u003cspan class=\"\"\u003e highly controlled quantities.\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered to meet the demanding requirements of modern healthcare,\u003c\/span\u003e\u003cspan class=\"\"\u003e it incorporates highly precise flow control systems alongside smart safety alarms.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its lightweight,\u003c\/span\u003e\u003cspan class=\"\"\u003e ergonomic layout makes it equally suited for crowded stationary bedside clinical setups and highly mobile emergency transport settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003eSP08\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003e3.8-inch interface screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eDevice Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003e1.5 kg (Highly portable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003e248 mm × 151.5 mm × 97 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eAccuracy Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003eWithin ±2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003eFlow Rate Settings Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"5,6,1,0\"\u003e0.1 mL\/h to 1500 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"5,6,1,1\"\u003e\n\u003cp data-path-to-node=\"5,6,1,2\"\u003e• \u003ci data-path-to-node=\"5,6,1,2\" data-index-in-node=\"2\"\u003e0.1–100 mL\/h (increments of 0.1 mL\/h)\u003c\/i\u003e\u003c\/p\u003e\n\u003cbr data-path-to-node=\"5,6,1,3\"\u003e\n\u003cp data-path-to-node=\"5,6,1,4\"\u003e• \u003ci data-path-to-node=\"5,6,1,4\" data-index-in-node=\"2\"\u003e101–1500 mL\/h (increments of 1 mL\/h)\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003e\u003cb data-path-to-node=\"5,7,0,0\" data-index-in-node=\"0\"\u003eSyringe Compatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003e5 mL, 10 mL, 20 mL, 30 mL, 50 mL, and 60 mL sizes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003e\u003cb data-path-to-node=\"5,8,0,0\" data-index-in-node=\"0\"\u003eInfusion Modes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003eRate (Speed) Mode, Time Mode, Volume Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,0,0\"\u003e\u003cb data-path-to-node=\"5,9,0,0\" data-index-in-node=\"0\"\u003eInjection Time Setting Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,1,0\"\u003e1 minute to 99 hours 59 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,0,0\"\u003e\u003cb data-path-to-node=\"5,10,0,0\" data-index-in-node=\"0\"\u003eKVO (Keep Vein Open) Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,1,0\"\u003eFixed at 2.5 mL\/h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,0,0\"\u003e\u003cb data-path-to-node=\"5,11,0,0\" data-index-in-node=\"0\"\u003eBattery Working Time\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,1,0\"\u003e4 to 8+ hours of continuous usage (lithium backup)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,0,0\"\u003e\u003cb data-path-to-node=\"5,12,0,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,1,0\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,0,0\"\u003e\u003cb data-path-to-node=\"5,13,0,0\" data-index-in-node=\"0\"\u003eOperating Environment\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,1,0\"\u003e5°C to 40°C; Relative humidity less than 80%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\" id=\"p-rc_1836f5e380e234c7-256\"\u003e\u003cspan class=\"citation-686\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-686\"\u003eHigh Precision Performance:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-686 citation-end-686\"\u003e Ensures consistent delivery of powerful or sensitive medications with a tight accuracy limit of ±2%.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_1836f5e380e234c7-257\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eKeep Vein Open (KVO):\u003c\/b\u003e\u003cspan class=\"citation-685 citation-end-685\"\u003e Features a automated 2.5 mL\/h KVO trickle-flow safety setting that engages post-delivery to prevent backflow or clotting at the access site.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_1836f5e380e234c7-258\"\u003e\u003cspan class=\"citation-684\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-684\"\u003eFlexible Multi-Mode Functionality:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-684 citation-end-684\"\u003e Medical staff can select standard Speed\/Rate inputs, Speed + Time constraints, or Speed + Target Volume limits to best match complex prescriptions.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\" id=\"p-rc_1836f5e380e234c7-259\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eWide Universal Syringe Matching:\u003c\/b\u003e\u003cspan class=\"citation-683 citation-end-683\"\u003e Automatically accommodates and calibrates alongside 4 to 5 standard syringe dimensions ranging from fine 5 mL types up to high-volume 60 mL configurations.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\" id=\"p-rc_1836f5e380e234c7-260\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eErgonomic Portability:\u003c\/b\u003e\u003cspan class=\"citation-682 citation-end-682\"\u003e Built at a weight of only 1.5 kg with an accessible horizontal design profile that allows rapid deployment or pole mounting.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\" id=\"p-rc_1836f5e380e234c7-261\"\u003e\u003cspan class=\"citation-681\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-681\"\u003eIntuitive UI and Navigation:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-681 citation-end-681\"\u003e Features a vibrant, high-readability 3.8-inch display built to minimize programming errors and keep active parameters fully visible from across a patient bay.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\" id=\"p-rc_1836f5e380e234c7-262\"\u003e\u003cspan class=\"citation-680\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-680\"\u003eUninterrupted Mobile Battery Safety:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-680 citation-end-680\"\u003e Outfitted with an integrated rechargeable lithium-ion core capable of driving continuous infusion for hours when primary line power drops out or during patient transfers.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\" id=\"p-rc_1836f5e380e234c7-263\"\u003e\u003cspan class=\"citation-679\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-679\"\u003eComprehensive Smart Sensory Alarms:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-679 citation-end-679\"\u003e Built with precise occlusive backpressure and volume-exhaust detection limits to sound visual and audio alerts when fluid pathways encounter blocks.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\" id=\"p-rc_1836f5e380e234c7-264\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eIntensive Care \u0026amp; Operating Rooms:\u003c\/b\u003e\u003cspan class=\"citation-678 citation-end-678\"\u003e Used for administering exact titrations of vasoactive substances, anesthetics, and high-alert continuous intravenous drips in ICU or OT zones.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\" id=\"p-rc_1836f5e380e234c7-265\"\u003e\u003cspan class=\"citation-677\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-677\"\u003eNeonatal \u0026amp; Pediatric Wards:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-677 citation-end-677\"\u003e Ideal for young or low-weight patients where tiny volumes require extreme micro-dosing safety standards.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\" id=\"p-rc_1836f5e380e234c7-266\"\u003e\u003cspan class=\"citation-676\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-676\"\u003eEmergency \u0026amp; Trauma Transportation:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-676 citation-end-676\"\u003e Deployed inside active field ambulances and intra-hospital mobile transfer teams due to its low weight and rugged internal battery layout.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eGeneral Medical Wards \u0026amp; Research Labs:\u003c\/b\u003e Used for routine fluid management, clinical nutrition, or precise liquid delivery inside scientific testing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eIn The Box\u003c\/h3\u003e\n\u003col start=\"1\" data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e1 × SP08 Portable Syringe Pump Main Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\" id=\"p-rc_1836f5e380e234c7-267\"\u003e\u003cspan class=\"citation-675 citation-end-675\"\u003e1 × AC Power Cord\/Charging Adapter\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003e1 × Heavy-Duty Mounting Bracket\/Clamp Assembly (for IV Poles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003e1 × Comprehensive User\/Operation Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003e1 × Manufacturer Warranty Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974105481434,"sku":"7615","price":14100.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/Syringe-Pump_spo8.avif?v=1782905812","url":"https:\/\/www.kaaryamedical.com\/products\/kaarya-sp08-portable-syring-pump","provider":"KDS Enterprise","version":"1.0","type":"link"}