{"product_id":"kaarya-9009b-multipara-patient-monitor","title":"Kaarya 9009B Multipara Patient Monitor","description":"\u003ch3 data-path-to-node=\"1\" class=\"\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan class=\"\"\u003eThe Kaarya 9009B is a robust,\u003c\/span\u003e\u003cspan class=\"\"\u003e lightweight,\u003c\/span\u003e\u003cspan class=\"\"\u003e and versatile 12.\u003c\/span\u003e\u003cspan class=\"\"\u003e1-inch multi-parameter patient monitor designed to support clinical staff in continuous physiological tracking.\u003c\/span\u003e\u003cspan class=\"\"\u003e Configured primarily as a 5-parameter cardiac monitor,\u003c\/span\u003e\u003cspan class=\"\"\u003e it provides continuous observation of vital signs across adult,\u003c\/span\u003e\u003cspan class=\"\"\u003e pediatric,\u003c\/span\u003e\u003cspan class=\"\"\u003e and neonatal patient profiles.\u003c\/span\u003e\u003cspan class=\"\"\u003e Built with a slender,\u003c\/span\u003e\u003cspan class=\"\"\u003e portable chassis and a clear TFT-LED color display,\u003c\/span\u003e\u003cspan class=\"\"\u003e it stands up to the rigorous demands of peri-anesthesia,\u003c\/span\u003e\u003cspan class=\"\"\u003e intensive care units (ICU),\u003c\/span\u003e\u003cspan class=\"\"\u003e coronary care units (CCU),\u003c\/span\u003e\u003cspan class=\"\"\u003e and intra-hospital transit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003eMonitor Configuration\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003e5-Parameter Configuration Standard \u003ci data-path-to-node=\"5,1,1,0\" data-index-in-node=\"35\"\u003e(Upgradable to 6-Para\/Dual-IBP \u0026amp; \u003cspan class=\"math-inline\" data-math=\"EtCO_2\" data-index-in-node=\"68\"\u003e$EtCO_2$\u003c\/span\u003e)\u003c\/i\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eMonitored Parameters\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003eECG (Electrocardiogram), \u003cspan class=\"math-inline\" data-math=\"SpO_2\" data-index-in-node=\"25\"\u003e$SpO_2$\u003c\/span\u003e (Pulse Oximetry), NIBP (Non-Invasive Blood Pressure), RESP (Respiration Rate), TEMP (Temperature), PR (Pulse Rate)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eDisplay Screen\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003e12.1-inch High-Resolution Color TFT LCD \/ LED Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003ePatient Demographics\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003eAdult, Pediatric, and Neonatal compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eECG Lead Options\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003eStandard 5-lead configuration with 12-lead software interpretation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003eNIBP Measurement Mode\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003eManual, Automatic, or Continuous tracking intervals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003e\u003cb data-path-to-node=\"5,7,0,0\" data-index-in-node=\"0\"\u003eNIBP Intervals (Auto)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003eUser-adjustable sequence from 1 minute up to 90 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003e\u003cb data-path-to-node=\"5,8,0,0\" data-index-in-node=\"0\"\u003eNIBP Tech \u0026amp; Protection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003eOscillometric method with automated double overpressure safety protection (software + hardware)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,0,0\"\u003e\u003cb data-path-to-node=\"5,9,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"math-inline\" data-math=\"SpO_2\" data-index-in-node=\"0\"\u003e$SpO_2$\u003c\/span\u003e Technology\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,1,0\"\u003eNellcor compatibility standard; digital signal artifact resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,0,0\"\u003e\u003cb data-path-to-node=\"5,10,0,0\" data-index-in-node=\"0\"\u003ePulse Rate Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,1,0\"\u003e20 bpm to 254 bpm (\u003cspan class=\"math-inline\" data-math=\"\\pm\" data-index-in-node=\"19\"\u003e$\\pm$\u003c\/span\u003e3 bpm accuracy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,0,0\"\u003e\u003cb data-path-to-node=\"5,11,0,0\" data-index-in-node=\"0\"\u003eInternal Data Storage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,1,0\"\u003eFlash Memory: Stores up to 2,000 NIBP datasets \u0026amp; 30,000 \u003cspan class=\"math-inline\" data-math=\"SpO_2\" data-index-in-node=\"56\"\u003e$SpO_2$\u003c\/span\u003e events\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,0,0\"\u003e\u003cb data-path-to-node=\"5,12,0,0\" data-index-in-node=\"0\"\u003eTrend Evaluation Data\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,1,0\"\u003e7-day continuous graphical and tabular trend chart recall; 60 alarm event records; 6,000 seconds of raw ECG waveform recall\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,0,0\"\u003e\u003cb data-path-to-node=\"5,13,0,0\" data-index-in-node=\"0\"\u003ePower Architecture\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,1,0\"\u003eUniversal AC 100V–240V, 50\/60Hz input voltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,14,0,0\"\u003e\u003cb data-path-to-node=\"5,14,0,0\" data-index-in-node=\"0\"\u003eBattery Composition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,14,1,0\"\u003eInternal high-capacity rechargeable Lithium battery backup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,15,0,0\"\u003e\u003cb data-path-to-node=\"5,15,0,0\" data-index-in-node=\"0\"\u003eNet Structural Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,15,1,0\"\u003e3.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\" id=\"p-rc_6873e9ce50912066-174\"\u003e\u003cspan class=\"citation-303\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-303\"\u003eMulti-Stage Alarm Systems:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-303 citation-end-303\"\u003e Features a 3-level coordinated audio and visual alarm framework covering user-customizable upper and lower limits for Heart Rate, \u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"SpO_2\" data-index-in-node=\"157\"\u003e$SpO_2$\u003c\/span\u003e\u003cspan class=\"citation-302 citation-end-302\"\u003e, Systolic, Diastolic, and Mean Arterial Pressure (MAP).\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_6873e9ce50912066-175\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eClinical Interference Shielding:\u003c\/b\u003e\u003cspan class=\"citation-301 citation-end-301\"\u003e Engineered with specialized hardware-level filtering that offers high resistance to noise generated by defibrillators and high-frequency electrosurgical units (HK \/ surgical knives).\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_6873e9ce50912066-176\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eAdvanced ECG Diagnostics:\u003c\/b\u003e\u003cspan class=\"citation-300 citation-end-300\"\u003e Supports real-time ST-segment analysis, arrhythmia tracking, and a built-in pacemaker detection switch to manage complex cardiac anomalies.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\" id=\"p-rc_6873e9ce50912066-177\"\u003e\u003cspan class=\"citation-299\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-299\"\u003eFreeze-Frame Layout:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-299 citation-end-299\"\u003e Allows healthcare workers to instantly freeze active real-time waveforms on-screen to thoroughly examine subtle physiological disruptions.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\" id=\"p-rc_6873e9ce50912066-178\"\u003e\u003cspan class=\"citation-298\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-298\"\u003eNetwork Integration Capability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-298 citation-end-298\"\u003e Configured to integrate into wired or wireless central nursing monitoring infrastructure (CMS) for ward-wide tracking.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eComprehensive Patient Adaptation:\u003c\/b\u003e Features pre-configured safety thresholds tailored specifically to the patient category, preventing accidental over-inflation of blood pressure cuffs on neonatal or pediatric limbs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eUnique Architecture Footprint:\u003c\/b\u003e Thinner, balanced form-factor that is light enough for immediate un-docking during urgent point-to-point bedside handoffs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eExpansive Trend Review:\u003c\/b\u003e Built-in high-capacity flash architecture eliminates immediate reliance on external media, permitting clinicians to check patient recovery records over a rolling 7-day scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\" id=\"p-rc_6873e9ce50912066-179\"\u003e\u003cspan class=\"citation-297\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-297\"\u003eIntensive Care \u0026amp; Coronary Care (ICU \/ CCU):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-297 citation-end-297\"\u003e Continuous monitoring of unstable cardiac or respiratory patients who require multi-parameter observation.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eOperating Rooms \u0026amp; Recovery Wards (OR \/ PACU):\u003c\/b\u003e Monitoring vital signs during surgical intervention and anesthesia recovery phases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003ePatient Transport \u0026amp; Emergency Transfers:\u003c\/b\u003e Utilized inside the hospital during ward transfers, relying heavily on the internal battery pack and lightweight frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eKaarya KAA-9009B Multipara Patient Monitor Main Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\" id=\"p-rc_6873e9ce50912066-180\"\u003e\u003cspan class=\"citation-296 citation-end-296\"\u003e5-Lead Patient ECG Cable Assembly\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\" id=\"p-rc_6873e9ce50912066-181\"\u003e\u003cspan class=\"citation-295 citation-end-295\"\u003eAdult NIBP Cuff with Inflation Extension Hose\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\" id=\"p-rc_6873e9ce50912066-182\"\u003e\u003cspan class=\"citation-294 citation-end-294\"\u003eReusable Finger \u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"SpO_2\" data-index-in-node=\"16\"\u003e$SpO_2$\u003c\/span\u003e\u003cspan class=\"citation-293 citation-end-293\"\u003e Sensor (Adult Standard)\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eSkin Temperature Probe (Surface\/Skin type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\" id=\"p-rc_6873e9ce50912066-183\"\u003e\u003cspan class=\"citation-292 citation-end-292\"\u003eIntegrated Rechargeable Lithium Battery\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eMedical Grade AC Power Supply Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eUser Instruction \u0026amp; Operational Reference Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974112067802,"sku":"7684","price":19999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/7_7821fc6f-eac8-4102-8ea2-f22c992df6fa.jpg?v=1782654778","url":"https:\/\/www.kaaryamedical.com\/products\/kaarya-9009b-multipara-patient-monitor","provider":"KDS Enterprise","version":"1.0","type":"link"}