{"product_id":"contec-sp80b-spirometar","title":"CONTEC SP80B Spirometer with Software and USB","description":"\u003ch3 data-path-to-node=\"1\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\" id=\"p-rc_c05d23d60ea5db5e-640\"\u003e\u003cspan class=\"citation-2293 citation-end-2293\"\u003eThe CONTEC SP80B is a compact, handheld spirometer designed for evaluating and monitoring lung conditions.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-2292 citation-end-2292\"\u003eIt utilizes an advanced infrared signal acquisition mode to measure relative pulmonary parameters.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-2291 citation-end-2291\"\u003eFeaturing an integrated 2.8-inch high-definition screen, it provides real-time testing feedback alongside immediate visual flow-volume and volume-time graphs.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e The device operates seamlessly as a standalone unit or can sync via Bluetooth and USB to companion mobile apps and dedicated Windows PC software for clinical-grade record keeping and longitudinal trend analysis. \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"4\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,1,0,0\"\u003e\u003cb data-path-to-node=\"4,1,0,0\" data-index-in-node=\"0\"\u003eDisplay Mode\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,1,1,0\"\u003e2.8'' High-Definition Color Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,2,0,0\"\u003e\u003cb data-path-to-node=\"4,2,0,0\" data-index-in-node=\"0\"\u003eVolume Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,2,1,0\"\u003e0 to 10 Liters (L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,3,0,0\"\u003e\u003cb data-path-to-node=\"4,3,0,0\" data-index-in-node=\"0\"\u003eVolume Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,3,1,0\"\u003e± 3 % or ± 0.05 L (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,4,0,0\"\u003e\u003cb data-path-to-node=\"4,4,0,0\" data-index-in-node=\"0\"\u003eFlow Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,4,1,0\"\u003e0 L\/s to 16 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,5,0,0\"\u003e\u003cb data-path-to-node=\"4,5,0,0\" data-index-in-node=\"0\"\u003eFlow Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,5,1,0\"\u003e± 5 % or ± 0.2 L\/s (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,6,0,0\"\u003e\u003cb data-path-to-node=\"4,6,0,0\" data-index-in-node=\"0\"\u003eData Connectivity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,6,1,0\"\u003eWireless Bluetooth and wired USB data line\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,7,0,0\"\u003e\u003cb data-path-to-node=\"4,7,0,0\" data-index-in-node=\"0\"\u003eData Storage Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,7,1,0\"\u003eMass storage supporting up to 9,999 test cases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,8,0,0\"\u003e\u003cb data-path-to-node=\"4,8,0,0\" data-index-in-node=\"0\"\u003eWorking Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,8,1,0\"\u003e60 mA to 200 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,9,0,0\"\u003e\u003cb data-path-to-node=\"4,9,0,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,9,1,0\"\u003eRechargeable 3.7V Lithium Battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,10,0,0\"\u003e\u003cb data-path-to-node=\"4,10,0,0\" data-index-in-node=\"0\"\u003eSafety Classification\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,10,1,0\"\u003eInternally powered equipment, Type BF applied part\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,11,0,0\"\u003e\u003cb data-path-to-node=\"4,11,0,0\" data-index-in-node=\"0\"\u003eIngress Protection Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,11,1,0\"\u003eIP22\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,12,0,0\"\u003e\u003cb data-path-to-node=\"4,12,0,0\" data-index-in-node=\"0\"\u003ePhysical Dimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,12,1,0\"\u003e160 mm (L) × 65 mm (W) × 45 mm (H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,13,0,0\"\u003e\u003cb data-path-to-node=\"4,13,0,0\" data-index-in-node=\"0\"\u003eDevice Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"4,13,1,0\"\u003e190 grams\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\" id=\"p-rc_c05d23d60ea5db5e-641\"\u003e\u003cspan class=\"citation-2290\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2290\"\u003eComprehensive Parameter Tracking:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2290 citation-end-2290\"\u003e Measures Forced Vital Capacity (FVC), Forced Expiratory Volume in 1 second (\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"FEV_1\" data-index-in-node=\"110\"\u003e$FEV_1$\u003c\/span\u003e\u003cspan class=\"citation-2289 citation-end-2289\"\u003e), the \u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"FEV_1\/FVC\" data-index-in-node=\"122\"\u003e$FEV_1\/FVC$\u003c\/span\u003e\u003cspan class=\"citation-2288 citation-end-2288\"\u003e ratio, Peak Expiratory Flow (PEF), and mid-flow rates (\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"FEF_{25}\" data-index-in-node=\"187\"\u003e$FEF_{25}$\u003c\/span\u003e\u003cspan class=\"citation-2287 citation-end-2287\"\u003e, \u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"FEF_{50}\" data-index-in-node=\"197\"\u003e$FEF_{50}$\u003c\/span\u003e\u003cspan class=\"citation-2286 citation-end-2286\"\u003e, \u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"FEF_{75}\" data-index-in-node=\"207\"\u003e$FEF_{75}$\u003c\/span\u003e\u003cspan class=\"citation-2285 citation-end-2285\"\u003e, and \u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"FEF_{2575}\" data-index-in-node=\"221\"\u003e$FEF_{2575}$\u003c\/span\u003e\u003cspan class=\"citation-2284 citation-end-2284\"\u003e).\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\" id=\"p-rc_c05d23d60ea5db5e-642\"\u003e\u003cspan class=\"citation-2283\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2283\"\u003eDual Transmission Modes:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2283 citation-end-2283\"\u003e Effortless data uploading using integrated Bluetooth connectivity for mobile sync or a direct USB cable connection for PC transfer.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\" id=\"p-rc_c05d23d60ea5db5e-643\"\u003e\u003cspan class=\"citation-2282\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2282\"\u003eOn-Screen Graphical Evaluation:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2282 citation-end-2282\"\u003e Directly displays real-time flow-volume charts, volume-time charts, and historical trend lines without relying on a secondary device.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\" id=\"p-rc_c05d23d60ea5db5e-644\"\u003e\u003cspan class=\"citation-2281\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2281\"\u003eSmart Indicator Systems:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2281 citation-end-2281\"\u003e Includes a built-in health state indication (traffic light style assessment), over-limit prompt sensors for volume\/flow, and a dedicated 6-second expiration countdown indicator.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\" id=\"p-rc_c05d23d60ea5db5e-645\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eIntegrated Calibration Routine:\u003c\/b\u003e\u003cspan class=\"citation-2280 citation-end-2280\"\u003e Features an integrated self-calibration function to guarantee long-term clinical reading accuracy.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\" id=\"p-rc_c05d23d60ea5db5e-646\"\u003e\u003cspan class=\"citation-2279\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2279\"\u003eHigh Autonomy:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2279 citation-end-2279\"\u003e Operates perfectly as an independent standalone device; daily testing can be completed without ever loading a smartphone app or PC software.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_c05d23d60ea5db5e-647\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eMassive Built-in Memory:\u003c\/b\u003e\u003cspan class=\"citation-2278 citation-end-2278\"\u003e Avoids frequent clearing cycles by archiving up to 9,999 multi-waveform patient test records internally.\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_c05d23d60ea5db5e-648\"\u003e\u003cspan class=\"citation-2277\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2277\"\u003eUltra-Portable \u0026amp; Ergonomic:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2277 citation-end-2277\"\u003e Weighing just 190 grams with an eco-friendly rechargeable lithium battery, it is highly optimized for travel and on-the-go checks.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\" id=\"p-rc_c05d23d60ea5db5e-649\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eOne-Button Efficiency:\u003c\/b\u003e\u003cspan class=\"citation-2276 citation-end-2276\"\u003e Simplified user interface enables patients to initiate, capture, and store complex lung maneuvers with a single click.\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eRoutine Clinical Monitoring:\u003c\/b\u003e Utilized within hospitals and general physician clinics as an easy-to-sanitize tool for standard pulmonary screening and patient updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\" id=\"p-rc_c05d23d60ea5db5e-650\"\u003e\u003cspan class=\"citation-2275\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-2275\"\u003eHome Respiratory Management:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-2275 citation-end-2275\"\u003e Well-suited for individuals managing dynamic conditions like Asthma, COPD, or Cystic Fibrosis who require daily, independent, and documented tracking of airway limits.\u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eTreatment \u0026amp; Indicator Assessment:\u003c\/b\u003e Used to measure the overall therapeutic success of respiratory prescriptions, evaluate post-surgical rehabilitation progress, or complete general physical routine tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\" id=\"p-rc_c05d23d60ea5db5e-651\"\u003e\u003cspan class=\"citation-2274 citation-end-2274\"\u003eCONTEC SP80B Spirometer Device\u003csup class=\"superscript\" data-turn-source-index=\"20\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\" id=\"p-rc_c05d23d60ea5db5e-652\"\u003e\u003cspan class=\"citation-2273 citation-end-2273\"\u003ePC Analysis Software\u003csup class=\"superscript\" data-turn-source-index=\"21\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\" id=\"p-rc_c05d23d60ea5db5e-653\"\u003e\u003cspan class=\"citation-2272 citation-end-2272\"\u003eUSB Data Line\/Charging Cable\u003csup class=\"superscript\" data-turn-source-index=\"22\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\" id=\"p-rc_c05d23d60ea5db5e-654\"\u003e\u003cspan class=\"citation-2271 citation-end-2271\"\u003eRigid Disposable Mouthpiece\u003csup class=\"superscript\" data-turn-source-index=\"23\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\"\u003eOfficial User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47967664439514,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/Respbuy-Contec-SP80B-Spirometer_jpg.webp?v=1782660549","url":"https:\/\/www.kaaryamedical.com\/products\/contec-sp80b-spirometar","provider":"KDS Enterprise","version":"1.0","type":"link"}