{"product_id":"contec-sp10-spirometer","title":"Contec Hand Held CMS-SP10 Spirometer","description":"\u003ch3 class=\"\" data-path-to-node=\"1\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan class=\"citation-1902 citation-end-1902\"\u003eThe Contec CMS-SP10 is an ultra-thin, portable handheld spirometer designed for checking and monitoring lung conditions.\u003c\/span\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"citation-1901 citation-end-1901\"\u003eAdopting a reliable infrared mode for measuring relative airflow items, it operates as a lightweight, standalone screening unit.\u003c\/span\u003e\u003cspan class=\"\"\u003e It features a built-in 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e8\" color LCD display to show critical respiratory parameters and real-time waveforms.\u003c\/span\u003e\u003cspan class=\"\"\u003e This device makes it easy to measure and track pulmonary function without needing bulky equipment or constant smartphone pairing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\" data-path-to-node=\"3\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003ctable style=\"width: 100.036%;\" data-path-to-node=\"4\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,1,0,0\"\u003eDisplay Mode\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,1,1,0\"\u003e1.8'' TFT Color Screen (LED Backlight), 160 x 128 pixels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,2,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,2,0,0\"\u003eMeasured Parameters\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,2,1,0\"\u003eFVC, FEV1, FEV1%, PEF, FEF25, FEF75, FEF2575\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,3,0,0\"\u003eVolume Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,3,1,0\"\u003e0 to 10 Liters (L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,4,0,0\"\u003eVolume Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,4,1,0\"\u003e±3% or ±0.05 Liters (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,5,0,0\"\u003eFlow Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,5,1,0\"\u003e1 L\/s to 16 L\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,6,0,0\"\u003eFlow Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,6,1,0\"\u003e±10% or ±0.3 L\/s (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,7,0,0\"\u003ePower Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,7,1,0\"\u003eDC 3.7V Rechargeable Lithium Battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,8,0,0\"\u003eWorking Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,8,1,0\"\u003e60 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,9,0,0\"\u003eBattery Life\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,9,1,0\"\u003eApproximately 4 hours of continuous use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,10,0,0\"\u003eSafety Classification\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,10,1,0\"\u003eInternally powered equipment, Type BF applied part\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,11,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,11,0,0\"\u003eData Memory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,11,1,0\"\u003eStores up to 9,999 test records (depending on specific firmware version updates)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,12,0,0\"\u003eHighest Flow Resistance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,12,1,0\"\u003e6 Pa\/L\/s (typically occurring at 14 L\/s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,13,0,0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,13,1,0\"\u003e97mm (L) × 89mm (W) × 36mm (H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.89%;\"\u003e\u003cspan data-path-to-node=\"4,14,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,14,0,0\"\u003eNet Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.8943%;\"\u003e\u003cspan data-path-to-node=\"4,14,1,0\"\u003e150 grams\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-540\" data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003eDual Graphing Display:\u003c\/b\u003e\u003cspan class=\"citation-1900 citation-end-1900\"\u003e Instantly renders Flow Rate-Volume charts and Volume-Time charts on the color screen to assist in assessing test validity.\u003csup data-turn-source-index=\"3\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-541\" data-path-to-node=\"6,1,0\"\u003e\u003cspan class=\"citation-1899\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003e\u003cspan class=\"citation-1899\"\u003eOn-Board Data Management:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1899 citation-end-1899\"\u003e Allows users to store, review, and delete records directly from the device memory.\u003csup data-turn-source-index=\"4\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-542\" data-path-to-node=\"6,2,0\"\u003e\u003cspan class=\"citation-1898\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003e\u003cspan class=\"citation-1898\"\u003eIntelligent Alerts:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1898 citation-end-1898\"\u003e Automated information prompts flag the user when a patient's volume or flow goes beyond established structural limits.\u003csup data-turn-source-index=\"5\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-543\" data-path-to-node=\"6,3,0\"\u003e\u003cspan class=\"citation-1897\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003e\u003cspan class=\"citation-1897\"\u003eSmart Power Optimization:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1897 citation-end-1897\"\u003e Features an automatic power-off mechanism that triggers after one minute of inactivity to preserve battery health.\u003csup data-turn-source-index=\"6\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-544\" data-path-to-node=\"6,4,0\"\u003e\u003cspan class=\"citation-1896\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,4,0\"\u003e\u003cspan class=\"citation-1896\"\u003eScaling \u0026amp; Calibration:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1896 citation-end-1896\"\u003e Built-in system support for data scaling to keep sensor readings reliable over time.\u003csup data-turn-source-index=\"7\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-545\" data-path-to-node=\"6,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,5,0\"\u003ePC Connectivity:\u003c\/b\u003e\u003cspan class=\"citation-1895 citation-end-1895\"\u003e Includes a dedicated USB data interface link to transfer stored testing trends and patient databases over to desktop management software.\u003csup data-turn-source-index=\"8\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-546\" data-path-to-node=\"8,0,0\"\u003e\u003cspan class=\"citation-1894\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003cspan class=\"citation-1894\"\u003eMaximum Portability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1894 citation-end-1894\"\u003e Weighing just 150g, it is exceptionally compact, making it convenient to transport for field screenings or move between clinic rooms.\u003csup data-turn-source-index=\"9\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-547\" data-path-to-node=\"8,1,0\"\u003e\u003cspan class=\"citation-1893\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003e\u003cspan class=\"citation-1893\"\u003eComprehensive Metrics:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1893 citation-end-1893\"\u003e Tracks vital indices including Forced Vital Capacity (FVC), Peak Expiratory Flow (PEF), and the crucial FEV1\/FVC ratio.\u003csup data-turn-source-index=\"10\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-548\" data-path-to-node=\"8,2,0\"\u003e\u003cspan class=\"citation-1892\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003e\u003cspan class=\"citation-1892\"\u003ePatient Condition Comparison:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1892 citation-end-1892\"\u003e Automatically evaluates the testee’s respiratory performance by calculating and displaying the ratio of the measured value against predicted healthy baseline values.\u003csup data-turn-source-index=\"11\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-549\" data-path-to-node=\"10,0,0\"\u003e\u003cspan class=\"citation-1891\"\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e\u003cspan class=\"citation-1891\"\u003eRoutine Clinical Screenings:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1891 citation-end-1891\"\u003e Employed by healthcare practitioners in general hospital wards, small clinics, and diagnostic labs for regular pulmonary function testing (PFT).\u003csup data-turn-source-index=\"12\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-550\" data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eChronic Condition Management:\u003c\/b\u003e\u003cspan class=\"citation-1890 citation-end-1890\"\u003e Frequently utilized for monitoring the daily baseline and tracking trends of patients diagnosed with Asthma, COPD, or other restrictive and obstructive lung conditions.\u003csup data-turn-source-index=\"13\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-551\" data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eHome Health Care:\u003c\/b\u003e\u003cspan class=\"citation-1889 citation-end-1889\"\u003e Its straightforward, standalone interface allows home users to record accurate lung data without needing specialized clinical training.\u003csup data-turn-source-index=\"14\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 × Contec CMS-SP10 Handheld Spirometer Main Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-552\" data-path-to-node=\"12,1,0\"\u003e\u003cspan class=\"citation-1888 citation-end-1888\"\u003e1 × Plastic Reusable Turbine\/Mouthpiece\u003csup data-turn-source-index=\"15\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-553\" data-path-to-node=\"12,2,0\"\u003e\u003cspan class=\"citation-1887 citation-end-1887\"\u003e1 × USB Data Line (for PC software sync)\u003csup data-turn-source-index=\"16\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-554\" data-path-to-node=\"12,3,0\"\u003e\u003cspan class=\"citation-1886 citation-end-1886\"\u003e1 × Power Adapter\/Charging Kit\u003csup data-turn-source-index=\"17\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-555\" data-path-to-node=\"12,4,0\"\u003e\u003cspan class=\"citation-1885 citation-end-1885\"\u003e1 × PC Data Management Software (download link or disc)\u003csup data-turn-source-index=\"18\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-556\" data-path-to-node=\"12,5,0\"\u003e\u003cspan class=\"citation-1884 citation-end-1884\"\u003e1 × User Manual\u003csup data-turn-source-index=\"19\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_297674475fbc28a7-557\" data-path-to-node=\"12,6,0\"\u003e\u003cspan class=\"citation-1883\"\u003e\u003c\/span\u003e\u003ci data-index-in-node=\"0\" data-path-to-node=\"12,6,0\"\u003e\u003cspan class=\"citation-1883\"\u003e1 × Nose Clip (Optional accessory)\u003c\/span\u003e\u003c\/i\u003e\u003cspan class=\"citation-1883 citation-end-1883\"\u003e\u003csup data-turn-source-index=\"20\" class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974098895066,"sku":"7533","price":17200.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/contec-hand-held-cms-sp10-spirometer-04_05_2026-46f97aec.avif?v=1782659743","url":"https:\/\/www.kaaryamedical.com\/products\/contec-sp10-spirometer","provider":"KDS Enterprise","version":"1.0","type":"link"}