{"product_id":"byond-byz-810-syringe-infusion-pump","title":"Byond Byz-810 Syringe Infusion Pump","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe Byond BYZ-810 is a portable,\u003c\/span\u003e\u003cspan class=\"\"\u003e compact,\u003c\/span\u003e\u003cspan class=\"\"\u003e and highly precise medical device designed for controlled delivery of essential therapeutics through multiple standard routes,\u003c\/span\u003e\u003cspan class=\"\"\u003e including intravenous (IV),\u003c\/span\u003e\u003cspan class=\"\"\u003e intramuscular (IM),\u003c\/span\u003e\u003cspan class=\"\"\u003e and subcutaneous lines.\u003c\/span\u003e\u003cspan class=\"\"\u003e Equipped with an innovative dual-display system (featuring both a high-definition LCD screen and a numerical digital tube),\u003c\/span\u003e\u003cspan class=\"\"\u003e it provides real-time tracking of parameters.\u003c\/span\u003e\u003cspan class=\"\"\u003e It features a standout \u003c\/span\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"434\" class=\"\"\u003eUnique Human Voice Alarm system\u003c\/b\u003e\u003cspan class=\"\"\u003e alongside standard audio-visual cues to maximize clinical safety and simplify troubleshooting during critical healthcare workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\" class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003ctable data-path-to-node=\"6\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,0,0\"\u003e\u003cb data-path-to-node=\"6,1,0,0\" data-index-in-node=\"0\"\u003eProduct Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,1,0\"\u003eSingle-Channel Syringe Infusion Pump\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,0,0\"\u003e\u003cb data-path-to-node=\"6,2,0,0\" data-index-in-node=\"0\"\u003eCompatible Syringe Sizes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,1,0\"\u003e10 mL, 20 mL, 30 mL, 50\/60 mL (Supports all major brands after calibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,3,0,0\"\u003e\u003cb data-path-to-node=\"6,3,0,0\" data-index-in-node=\"0\"\u003eInfusion Flow Rate Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"6,3,1,0\"\u003e• \u003cb data-path-to-node=\"6,3,1,0\" data-index-in-node=\"2\"\u003e10 mL Syringe:\u003c\/b\u003e 0.1 – 300.0 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,3,1,1\"\u003e\n\u003cp data-path-to-node=\"6,3,1,2\"\u003e• \u003cb data-path-to-node=\"6,3,1,2\" data-index-in-node=\"2\"\u003e20 mL Syringe:\u003c\/b\u003e 0.1 – 600.0 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,3,1,3\"\u003e\n\u003cp data-path-to-node=\"6,3,1,4\"\u003e• \u003cb data-path-to-node=\"6,3,1,4\" data-index-in-node=\"2\"\u003e30 mL Syringe:\u003c\/b\u003e 0.1 – 900.0 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,3,1,5\"\u003e\n\u003cp data-path-to-node=\"6,3,1,6\"\u003e• \u003cb data-path-to-node=\"6,3,1,6\" data-index-in-node=\"2\"\u003e50\/60 mL Syringe:\u003c\/b\u003e 0.1 – 1,500.0 mL\/h (increments of 0.1 mL\/h up to 999.9 mL\/h)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,0,0\"\u003e\u003cb data-path-to-node=\"6,4,0,0\" data-index-in-node=\"0\"\u003eFlow Rate Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,1,0\"\u003eWithin ±3% (Mechanical precision within ±2%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,5,0,0\"\u003e\u003cb data-path-to-node=\"6,5,0,0\" data-index-in-node=\"0\"\u003eBolus Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"6,5,1,0\"\u003e• \u003cb data-path-to-node=\"6,5,1,0\" data-index-in-node=\"2\"\u003e10 mL:\u003c\/b\u003e 240 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,5,1,1\"\u003e\n\u003cp data-path-to-node=\"6,5,1,2\"\u003e• \u003cb data-path-to-node=\"6,5,1,2\" data-index-in-node=\"2\"\u003e20 mL:\u003c\/b\u003e 480 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,5,1,3\"\u003e\n\u003cp data-path-to-node=\"6,5,1,4\"\u003e• \u003cb data-path-to-node=\"6,5,1,4\" data-index-in-node=\"2\"\u003e30 mL:\u003c\/b\u003e 720 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,5,1,5\"\u003e\n\u003cp data-path-to-node=\"6,5,1,6\"\u003e• \u003cb data-path-to-node=\"6,5,1,6\" data-index-in-node=\"2\"\u003e50\/60 mL:\u003c\/b\u003e 1,200 mL\/h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,6,0,0\"\u003e\u003cb data-path-to-node=\"6,6,0,0\" data-index-in-node=\"0\"\u003ePurge Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"6,6,1,0\"\u003e• \u003cb data-path-to-node=\"6,6,1,0\" data-index-in-node=\"2\"\u003e10 mL:\u003c\/b\u003e 300 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,6,1,1\"\u003e\n\u003cp data-path-to-node=\"6,6,1,2\"\u003e• \u003cb data-path-to-node=\"6,6,1,2\" data-index-in-node=\"2\"\u003e20 mL:\u003c\/b\u003e 600 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,6,1,3\"\u003e\n\u003cp data-path-to-node=\"6,6,1,4\"\u003e• \u003cb data-path-to-node=\"6,6,1,4\" data-index-in-node=\"2\"\u003e30 mL:\u003c\/b\u003e 900 mL\/h\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,6,1,5\"\u003e\n\u003cp data-path-to-node=\"6,6,1,6\"\u003e• \u003cb data-path-to-node=\"6,6,1,6\" data-index-in-node=\"2\"\u003e50\/60 mL:\u003c\/b\u003e 1,500 mL\/h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,7,0,0\"\u003e\u003cb data-path-to-node=\"6,7,0,0\" data-index-in-node=\"0\"\u003eVolume Limit Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,7,1,0\"\u003e0.1 mL – 9,999.9 mL (0.1 mL increments)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,8,0,0\"\u003e\u003cb data-path-to-node=\"6,8,0,0\" data-index-in-node=\"0\"\u003eTotal Accumulated Volume\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,8,1,0\"\u003e0.1 mL – 9,999.9 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,0,0\"\u003e\u003cb data-path-to-node=\"6,9,0,0\" data-index-in-node=\"0\"\u003eKVO (Keep-Vein-Open) Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,1,0\"\u003e1.0 mL\/h to 5.0 mL\/h (Adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,10,0,0\"\u003e\u003cb data-path-to-node=\"6,10,0,0\" data-index-in-node=\"0\"\u003eOcclusion Pressure Levels\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp data-path-to-node=\"6,10,1,0\"\u003eThree levels selectable:\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,10,1,1\"\u003e\n\u003cp data-path-to-node=\"6,10,1,2\"\u003e• \u003cb data-path-to-node=\"6,10,1,2\" data-index-in-node=\"2\"\u003eHigh:\u003c\/b\u003e 800 mmHg ±200 mmHg\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,10,1,3\"\u003e\n\u003cp data-path-to-node=\"6,10,1,4\"\u003e• \u003cb data-path-to-node=\"6,10,1,4\" data-index-in-node=\"2\"\u003eMedium:\u003c\/b\u003e 600 mmHg ±100 mmHg\u003c\/p\u003e\n\u003cbr data-path-to-node=\"6,10,1,5\"\u003e\n\u003cp data-path-to-node=\"6,10,1,6\"\u003e• \u003cb data-path-to-node=\"6,10,1,6\" data-index-in-node=\"2\"\u003eLow:\u003c\/b\u003e 300 mmHg ±100 mmHg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,11,0,0\"\u003e\u003cb data-path-to-node=\"6,11,0,0\" data-index-in-node=\"0\"\u003ePower Source\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,11,1,0\"\u003eAC 100V – 240V, 50\/60Hz; 12V DC car charging support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,12,0,0\"\u003e\u003cb data-path-to-node=\"6,12,0,0\" data-index-in-node=\"0\"\u003eInternal Battery Backup\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,12,1,0\"\u003eRechargeable Lithium battery (≥1,600 mAh) offering up to 4 hours of backup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,13,0,0\"\u003e\u003cb data-path-to-node=\"6,13,0,0\" data-index-in-node=\"0\"\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,13,1,0\"\u003e30VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,14,0,0\"\u003e\u003cb data-path-to-node=\"6,14,0,0\" data-index-in-node=\"0\"\u003eIngress Protection Level\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,14,1,0\"\u003eIPX4 (Splash-proof design)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,15,0,0\"\u003e\u003cb data-path-to-node=\"6,15,0,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,15,1,0\"\u003e280 mm (L) × 210 mm (W) × 130 mm (H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,16,0,0\"\u003e\u003cb data-path-to-node=\"6,16,0,0\" data-index-in-node=\"0\"\u003eNet Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,16,1,0\"\u003e2.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\" id=\"p-rc_918a2c14e03fe6cb-320\"\u003e\u003cspan class=\"citation-995\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-995\"\u003eThree Flexible Infusion Modes:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-995\"\u003e Tailors medication administration to multiple clinical scenarios using \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"102\"\u003e\u003cspan class=\"citation-995\"\u003eRate Mode\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-995\"\u003e, \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"113\"\u003e\u003cspan class=\"citation-995\"\u003eTime-Volume Mode\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-995\"\u003e, or \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"134\"\u003e\u003cspan class=\"citation-995\"\u003eDosage-Weight Mode\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-995 citation-end-995\"\u003e.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eIntelligent Syringe Recognition:\u003c\/b\u003e Automatically detects the size of the inserted syringe (10\/20\/30\/50\/60 mL) and adjusts safe delivery defaults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\" id=\"p-rc_918a2c14e03fe6cb-321\"\u003e\u003cspan class=\"citation-994\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-994\"\u003eAuto-Save Settings:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-994 citation-end-994\"\u003e Automatically records the configuration of the last injection so you don't lose key parameters if a quick reboot is needed.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\" id=\"p-rc_918a2c14e03fe6cb-322\"\u003e\u003cspan class=\"citation-993\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-993\"\u003eAnti-Bolus \u0026amp; Purge Functionality:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-993 citation-end-993\"\u003e Prevents large accidental doses of medication post-occlusion while keeping the line clear.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\" id=\"p-rc_918a2c14e03fe6cb-323\"\u003e\u003cspan class=\"citation-992\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-992\"\u003eFlexible Stackable Design:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-992 citation-end-992\"\u003e Individual pumps can be easily stacked on top of one another to deliver complex, multi-drug therapies side-by-side on a single IV pole.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\" id=\"p-rc_918a2c14e03fe6cb-324\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eVoice-Guided Safety:\u003c\/b\u003e\u003cspan class=\"citation-991 citation-end-991\"\u003e The integrated voice prompt acts as a vocal assistant, verbally calling out the specific error (e.g., \"Occlusion\", \"Battery Low\") and stopping operation instantly if a serious fault occurs.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\" id=\"p-rc_918a2c14e03fe6cb-325\"\u003e\u003cspan class=\"citation-990\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-990\"\u003eHigh Brand Compatibility:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-990 citation-end-990\"\u003e Open system architecture allows it to work safely with any manufacturer's syringe line following a simple configuration calibration.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\" id=\"p-rc_918a2c14e03fe6cb-326\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eEngineered for Low Noise:\u003c\/b\u003e\u003cspan class=\"citation-989 citation-end-989\"\u003e Utilizes high-end German motor driver ICs and internal components to minimize operational vibrations and noise, creating a quieter healing environment for the patient.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\" id=\"p-rc_918a2c14e03fe6cb-327\"\u003e\u003cspan class=\"citation-988\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-988\"\u003eIntensive Care Units (ICU \/ CCU \/ HDU):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-988 citation-end-988\"\u003e Crucial for delivering high-potency, life-support medications like vasopressors or antiarrhythmics where even slight dosage deviations carry massive risks.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\" id=\"p-rc_918a2c14e03fe6cb-328\"\u003e\u003cspan class=\"citation-987\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-987\"\u003eNeonatal \u0026amp; Pediatric Care (NICU \/ PICU):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-987 citation-end-987\"\u003e Perfect for small volume, highly precise fluid or medication delivery matching strict pediatric weight-based constraints.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\" id=\"p-rc_918a2c14e03fe6cb-329\"\u003e\u003cspan class=\"citation-986\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-986\"\u003eOperation Theatres (OT) \u0026amp; Anesthesia:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-986 citation-end-986\"\u003e Supports the precise administration of anesthetics and analgesics during continuous intraoperative care.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\" id=\"p-rc_918a2c14e03fe6cb-330\"\u003e\u003cspan class=\"citation-985\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-985\"\u003eEmergency Transport \u0026amp; Ambulances:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-985 citation-end-985\"\u003e Compact, lightweight layout backed by an integrated battery and 12V DC capability makes it highly suited for en-route emergency treatment.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"17\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"18\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,0,0\"\u003e1 × Byond BYZ-810 Syringe Infusion Pump Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,1,0\"\u003e1 × AC Power Cord (Three-pin plug)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,2,0\"\u003e1 × Pole Mounting Clamp \/ Screw Assembly (Attached or included for IV stand securing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,3,0\"\u003e1 × Comprehensive User Manual \/ Operating Instructions Booklet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,4,0\"\u003e1 × Manufacturer Warranty Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style is-at-scroll-start is-at-scroll-end\"\u003e\n\u003cdiv class=\"table-content\" data-hveid=\"0\" data-ved=\"0CAAQ3ecQahgKEwj226H7jaqVAxUAAAAAHQAAAAAQxwQ\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974102630618,"sku":"7593","price":19300.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/RespBuy-Byond-Syringe-Pump.webp?v=1782657513","url":"https:\/\/www.kaaryamedical.com\/products\/byond-byz-810-syringe-infusion-pump","provider":"KDS Enterprise","version":"1.0","type":"link"}