{"title":"CTG Machine","description":"","products":[{"product_id":"bistos-bt-350-ctg-machine","title":"Bistos-BT-350 CTG Machine","description":"\u003ch3 data-path-to-node=\"1\" class=\"\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan class=\"\"\u003eThe Bistos BT-350 is a microprocessor-based cardiotocograph (CTG) engineered for continuous antepartum monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e displaying,\u003c\/span\u003e\u003cspan class=\"\"\u003e and recording of the Fetal Heart Rate (FHR) and Uterine Contractions (UC\/TOCO).\u003c\/span\u003e\u003cspan class=\"\"\u003e Utilizing highly sensitive 1MHz multi-crystal pulsed Doppler probes,\u003c\/span\u003e\u003cspan class=\"\"\u003e it tracks fetal health dynamics precisely during non-stress tests (NST).\u003c\/span\u003e\u003cspan class=\"\"\u003e The device converts clinical biometric echoes into dual-waveform trends,\u003c\/span\u003e\u003cspan class=\"\"\u003e offering internal computerized CTG diagnostic interpretation to assist obstetric professionals in evaluating fetal well-being before labor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\" class=\"product-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003eMonitored Parameters\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003eFHR 1, FHR 2 (Twin Fetus), UC (Uterine Contraction), FM (Fetal Movement)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eSafety Certifications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003eKFDA, CE, FDA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eDisplay Screen\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003e7-inch Wide TFT Color LCD Screen (Rotatable layout)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003eFHR Technology\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003ePulsed Doppler with Autocorrelation processing (9-Crystal Probe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eUltrasound Frequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003e0.985 MHz (\u003cspan class=\"math-inline\" data-math=\"\\pm\" data-index-in-node=\"11\"\u003e$\\pm$\u003c\/span\u003e2% accuracy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003eUltrasound Intensity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003e10 mW\/\u003cspan class=\"math-inline\" data-math=\"cm^2\" data-index-in-node=\"6\"\u003e$cm^2$\u003c\/span\u003e or less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003e\u003cb data-path-to-node=\"5,7,0,0\" data-index-in-node=\"0\"\u003eFHR Measurement Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003eDual channel, 30 to 240 bpm \/ 50 to 210 bpm (\u003cspan class=\"math-inline\" data-math=\"\\pm\" data-index-in-node=\"45\"\u003e$\\pm$\u003c\/span\u003e2%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003e\u003cb data-path-to-node=\"5,8,0,0\" data-index-in-node=\"0\"\u003eUC (TOCO) Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003eExternal pressure transducer with DC to 0.5Hz frequency response\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,0,0\"\u003e\u003cb data-path-to-node=\"5,9,0,0\" data-index-in-node=\"0\"\u003eUC Measurement Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,1,0\"\u003e0 to 99 \/ 100 relative units (with Auto-Zero \/ Reference control)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,0,0\"\u003e\u003cb data-path-to-node=\"5,10,0,0\" data-index-in-node=\"0\"\u003eFetal Movement Detection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,1,0\"\u003eAuto-detection of dual fetal movement + manual event marker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,0,0\"\u003e\u003cb data-path-to-node=\"5,11,0,0\" data-index-in-node=\"0\"\u003eInternal Trend Memory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,1,0\"\u003e450 hours of continuous data retention (approx. 3 hours per patient for 150 patients)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,0,0\"\u003e\u003cb data-path-to-node=\"5,12,0,0\" data-index-in-node=\"0\"\u003ePrinter Mechanism\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,12,1,0\"\u003eHigh-speed integrated Thermal Array System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,0,0\"\u003e\u003cb data-path-to-node=\"5,13,0,0\" data-index-in-node=\"0\"\u003eCompatible Paper\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,13,1,0\"\u003eZ-fold format, 150 mm width \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"28\"\u003e$\\times$\u003c\/span\u003e 13.5 meters length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,14,0,0\"\u003e\u003cb data-path-to-node=\"5,14,0,0\" data-index-in-node=\"0\"\u003ePrinting Speed Options\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,14,1,0\"\u003e1, 2, 3 cm\/min (standard tracking) or 10 cm\/min (rapid trend dump)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,15,0,0\"\u003e\u003cb data-path-to-node=\"5,15,0,0\" data-index-in-node=\"0\"\u003eDevice Interfaces\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,15,1,0\"\u003eRS-232C, RJ45 Ethernet LAN, USB Host (Data export), Bluetooth \u003ci data-path-to-node=\"5,15,1,0\" data-index-in-node=\"62\"\u003e(Optional)\u003c\/i\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,16,0,0\"\u003e\u003cb data-path-to-node=\"5,16,0,0\" data-index-in-node=\"0\"\u003eMain Power Input\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,16,1,0\"\u003eAC 100V to 240V, 50\/60Hz (Output: DC 18V, 2.5A) \/ Consumption: 80VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,17,0,0\"\u003e\u003cb data-path-to-node=\"5,17,0,0\" data-index-in-node=\"0\"\u003eBattery Option\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,17,1,0\"\u003e14.8V Rechargeable Lithium-Ion battery pack (supports up to 3–5 hours)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,18,0,0\"\u003e\u003cb data-path-to-node=\"5,18,0,0\" data-index-in-node=\"0\"\u003eWaterproofing Grade\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,18,1,0\"\u003eTransducer Probes (DOP \u0026amp; UC): IPX8 Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,19,0,0\"\u003e\u003cb data-path-to-node=\"5,19,0,0\" data-index-in-node=\"0\"\u003eDimensions \u0026amp; Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,19,1,0\"\u003eMain Console: 326 (W) \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"22\"\u003e$\\times$\u003c\/span\u003e 276 (D) \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"37\"\u003e$\\times$\u003c\/span\u003e 96 (H) mm \/ Net Weight: 2.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\" id=\"p-rc_3aff10e6586bb0b1-75\"\u003e\u003cspan class=\"citation-143\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-143\"\u003eAutomated CTG Interpretation:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-143 citation-end-143\"\u003e Built-in algorithm analyzes baseline values, accelerations, decelerations, and fetal movement to display a diagnostics assessment summary on-screen or at the tail end of printouts.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\" id=\"p-rc_3aff10e6586bb0b1-76\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eCross-Channel Verification (CCV):\u003c\/b\u003e\u003cspan class=\"citation-142 citation-end-142\"\u003e Automatically cross-checks FHR signals when twin monitoring is active.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-141 citation-end-141\"\u003eIf the two Doppler channels register overlapping heart traces, a specialized alarm flags potential signal cross-talk or maternal signal contamination.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_3aff10e6586bb0b1-77\"\u003e\u003cspan class=\"citation-140\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-140\"\u003eIPX8 Waterproof Probes:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-140 citation-end-140\"\u003e Probes are completely sealed and certified for deep water-submersion, making the system ideal for water birth environments.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\" id=\"p-rc_3aff10e6586bb0b1-78\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDOP2 Heart Rate Offset:\u003c\/b\u003e\u003cspan class=\"citation-139 citation-end-139\"\u003e Includes a toggle feature that shifts the secondary twin FHR trend line vertically by +20 bpm on the grid display, preventing overlapping lines for clear legibility.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\" id=\"p-rc_3aff10e6586bb0b1-79\"\u003e\u003cspan class=\"citation-138\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-138\"\u003ePC \u0026amp; Central Station Compatibility:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-138 citation-end-138\"\u003e Directly bridges into BCM-350 Central Monitoring Software via LAN or RS-232 to remotely monitor up to 16 live bedside terminals.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eFlexible Graphic Modes:\u003c\/b\u003e The 7-inch rotatable LCD panel switches smoothly between real-time rolling trace grids and giant high-visibility font layouts for bedside checking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\" id=\"p-rc_3aff10e6586bb0b1-80\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eUSB Trend Data Portability:\u003c\/b\u003e\u003cspan class=\"citation-137 citation-end-137\"\u003e Allows nurses to dump stored internal records directly onto a standard USB memory stick without needing an active PC network hookup.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\" id=\"p-rc_3aff10e6586bb0b1-81\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eMulti-Language Interactive Interface:\u003c\/b\u003e\u003cspan class=\"citation-136 citation-end-136\"\u003e Supports 13 default internal system languages combined with an on-screen visual \"Quick Guide\" to simplify midwife operations.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\" id=\"p-rc_3aff10e6586bb0b1-82\"\u003e\u003cspan class=\"citation-135\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-135\"\u003eZoom-In Print Focus:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-135 citation-end-135\"\u003e Enlarges specific FHR windows on paper to help clinicians inspect localized, highly dynamic cardiac deceleration areas closer.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eUse Cases\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\" id=\"p-rc_3aff10e6586bb0b1-83\"\u003e\u003cspan class=\"citation-134\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-134\"\u003eObstetric Clinics \u0026amp; Private Practices:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-134 citation-end-134\"\u003e Conducting routine Non-Stress Tests (NST) to verify baseline cardiac safety curves during late-stage check-ups.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\" id=\"p-rc_3aff10e6586bb0b1-84\"\u003e\u003cspan class=\"citation-133\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-133\"\u003eHospital Labor Rooms \u0026amp; Delivery Suites:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-133 citation-end-133\"\u003e Continuous cardiotocography tracking during active stages of induced labor.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\" id=\"p-rc_3aff10e6586bb0b1-85\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eWater Birth Delivery Facilities:\u003c\/b\u003e\u003cspan class=\"citation-132 citation-end-132\"\u003e Safe fetal monitoring using fully submerged, water-tight transducer arrays.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eIn the Box\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eBistos BT-350 Fetal Monitor Main Station\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\" id=\"p-rc_3aff10e6586bb0b1-86\"\u003e\u003cspan class=\"citation-131 citation-end-131\"\u003e2 \u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"2\"\u003e$\\times$\u003c\/span\u003e\u003cspan class=\"citation-130 citation-end-130\"\u003e Waterproof Ultrasound Doppler Probes (FHR)\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\" id=\"p-rc_3aff10e6586bb0b1-87\"\u003e\u003cspan class=\"citation-129 citation-end-129\"\u003e1 \u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"2\"\u003e$\\times$\u003c\/span\u003e\u003cspan class=\"citation-128 citation-end-128\"\u003e External Uterine Contraction Pressure Probe (UC\/TOCO)\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003e1 \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"2\"\u003e$\\times$\u003c\/span\u003e Patient Handheld Event Marker Button Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003e3 \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"2\"\u003e$\\times$\u003c\/span\u003e Elastic Transducer Probe Positioning Belts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\"\u003e2 \u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"2\"\u003e$\\times$\u003c\/span\u003e Packs of Z-Fold Thermal Recording Paper Grid Packs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\" id=\"p-rc_3aff10e6586bb0b1-88\"\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003e1 \u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\times\" data-index-in-node=\"2\"\u003e$\\times$\u003c\/span\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003e 250ml Medical Ultrasound Coupling Gel Bottle\u003csup class=\"superscript\" data-turn-source-index=\"20\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,7,0\" id=\"p-rc_3aff10e6586bb0b1-89\"\u003e\u003cspan class=\"citation-125 citation-end-125\"\u003eMedical Grade External Power Adapter \u0026amp; Country-Specific AC Cord\u003csup class=\"superscript\" data-turn-source-index=\"21\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,8,0\" id=\"p-rc_3aff10e6586bb0b1-90\"\u003e\u003cspan class=\"citation-124 citation-end-124\"\u003eUser Operational Instruction \u0026amp; Field Service Manual\u003csup class=\"superscript\" data-turn-source-index=\"22\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kaarya","offers":[{"title":"Default Title","offer_id":47974112690394,"sku":"7702","price":55150.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7498\/2874\/files\/3173236044.webp?v=1781180213"}],"url":"https:\/\/www.kaaryamedical.com\/collections\/ctg-machine.oembed","provider":"KDS Enterprise","version":"1.0","type":"link"}